Utilitech 15 -Amp 125-volt Tamper Resistant Residential Decorator USB outlet Receptacles , White 2 -Pack
Item #2677690 |
Model #R1815D60AAC-WH2
Shipping
Sat, Nov 21
54 available
Delivery
54 available
Is this the right store? This can affect availability and delivery options.
Don't miss out on MyLowe's Money◊!
Here are some similar items...
Upgraded 3 USB ports for maximum usage for the family, added a reversible type C USB port for the increasingly popular electronic devices trend
Smart chip recognizes the individual device's charging protocols and requirements to optimize charging of electronic devices for fast and efficient charging of phones, tablets, gaming devices, e-readers and a host of other electronic devices
Type A and type C USB charging ports features a total output of 5V DC, 6.0 Amp, 30w (max 3.3A standalone), meets a variety of charging requirements to make sure your devices are charged at blazing-fast speeds, but not for laptops
Tamper resistant outlets blocks the access to the contacts unless a two-or-three-prong plug is inserted, preventing young children from inserting unwanted objects into the outlets
Works with 12 or 14 AWG for back wiring, compatible with all electrical boxes, decora devices, and wall plates
General | |||
|---|---|---|---|
Wire Type | Copper | Function Type | Receptacle outlet |
Industry Color | White | Type | USB outlet |
Style | Decorator | Grade | Residential |
Sub-Brand | N/A | USB Type | Type A/C |
Grounding Type | Grounded | Use Location | Indoor |
Package Quantity | 2 | Connection Type |
|
Manufacturer Color/Finish | White | Wiring Type | 3-wire grounding |
Features | |||
|---|---|---|---|
Programmable | No | Surge Protection | No |
Wireless | No | Wall Plate Included | No |
NEMA Configuration | 5-15R | Night Light | No |
Voice Controlled | No | Recessed | No |
Lockable | No | Weather Resistant | No |
Tamper Resistant | Yes | Number of Outlets | 2 |
Pop-Out | No | Power Indicator Light | No |
Volts | 125-volt | Audible Alarm | No |
Rust Resistant | No | Remote Controlled | No |
Hub Required | No | Self-Test | No |
Compatibility | |||
|---|---|---|---|
App Compatibility | No | Works with Android | No |
Wi-Fi Compatibility | No | Works with Amazon Alexa | No |
Bluetooth Compatibility | No | Works with SmartThings | No |
For Use with Mobile Homes | No | Works with the Google Assistant | No |
Smart Compatible | No | Works with iOS | No |
Works with Apple HomeKit | No | For Use with RVs | No |
Certifications | |||
|---|---|---|---|
CA Residents: Prop 65 Warning(s) | No | AFCI Protection | No |
Safety Listing | UL safety listing | GFCI Protection | No |
Warranty | |||
|---|---|---|---|
Warranty | 1-year | ||
Dimensions | |||
|---|---|---|---|
Amperage | 15 | ||
Miscellaneous | |||
|---|---|---|---|
UNSPSC | 39121300 | ||
Check out the Best Selling Electrical Outlets on Lowes.com
Ratings may include incentivized customer reviews.
What Customers Are Saying
The GFCI outlets with dual USB ports are convenient, providing both electrical and USB charging capabilities. Customers found the outlets easy to install with clear wiring instructions and appreciated the fast charging for devices. The extra USB port in the middle was a useful feature. However, some noted the outlets are larger in size, and the tamper-resistant receptacles were initially stiff. The 30A RV outlets were also well-received, with customers satisfied with the quality and ease of installation. A few mentioned the outlets were a bit tight in the electrical box, but overall the product performed as expected.
Customer review summary generated by AI, including incentivized reviews.I am happy with this product as it is the perfect fit and function
From 30 -Amp 125_SLASH_250-volt Industrial Round Dryer power outlet Receptacles , Black Verified Purchaser
30 amp receptacle
I got a new dryer and had to change the receptacle , it was an easy change but the new was a fuzz wider than the old electrical box.. it took a little force to get it into the old box which I did not want o change.. I installed it and it worked fine. Good quality.
From 30 -Amp 125_SLASH_250-volt Industrial Round Dryer power outlet Receptacles , Black Verified Purchaser
Just what I needed
This was the perfect replacement to our outdated outlet.
From 50 -Amp 125_SLASH_250-volt Industrial Round Range power outlet Receptacles , Black Verified Purchaser
Fair price
City code requires GFCI on all kitchen receptacles
From 20 -Amp 125-volt Tamper Resistant GFCI Residential Decorator Outlet Receptacles , Light almond 6 -Pack Verified Purchaser
Excellent will definitely buy again
Came on time all pieces there works great definitely worth the money
From 30 -Amp 125_SLASH_250-volt Industrial Round Dryer power outlet Receptacles , Black Verified Purchaser
78 Questions
6
Answers
[part 1/4] I intended to mount this outlet externally on a basement wall, using one of those thick grey PVC boxes.
By SJR1 on August 19, 2020[part 2/4] Although 2-1/8" depth is recommended by other users, Carlon E9802DRL fits this exact outlet perfectly,
By SJR1 on August 19, 2020[part 3/4] despite advertised as 1.98" depth and having a usable cavity depth of 1-13/16".
By SJR1 on August 19, 2020[part 4/4] The outlet will be flush against the back wall of the box, but this is ok because all wires enter the outlet from the top/bottom/sides.
By SJR1 on August 19, 2020I had the same question: What box should be used? My goal was to mount a box externally on a basement wall, one of those thick grey PVC boxes. Althoug
By SJR1 on August 18, 2020The receptacle dimensions are irrelevant. Use a 2 1/8" deep 1900 box (4" square) and a 1/2" raised 2-gang plaster frame and you will have no problems. This receptacle will not fit a single gang box.
By TomB2 on July 19, 20186
Answers
I would use a 2 1/8' deep 1900 box and a 1 gang plaster ring.
By TomB2 on May 25, 2023The 2 gang box sold at Lowe's is only 2.25" deep. you need at least 2.75-3" for back of outlet clearance. Must also purchase extender but its no longer weather tight without applying silicone.
By Joe on May 16, 2018Depending on the box it will fit either but is easier to wire in a double gang box because of the extra reoom.
By BobB on March 16, 2016Requires a double gang (4" square) deep box. The outlet screws to the cover plate (not the box) then the cover screws to the box. Works fine.
By MobileWelder on September 5, 2015I could not get it to fit in an old recessed 2x4 outlet box.
By Charlie on December 20, 2014suggest double and deep.
By abidehandy on August 9, 20145
Answers
New code requires the outlet to be rated for ev use due to the continuous power draw. The other answers are to old. A charger can melt these outlets
By josh on January 30, 2026it can charge a Tesla, but under 30 amps, This outlet is for range for short time load. Telsa charge can be under a load for hours and can overheat the outlet. This outlet should not be labeled industrial, see attached PDF, no where it says it is industrial.
By Cindy on April 4, 2025Yes, it can. Post back with electrical requirements for more info.
By TomB2 on June 20, 2024Yes, the Tesla charger that comes with the car comes with a NEMA 14-50 plug. Install it with a 50 amp circuit breaker and 6 awg wire.
By Bedevere on March 1, 2018Whether this receptacle can be used to charge a Tesla depends on the power requirements of the charger, but you haven't provided that information. I suspect, however, that the requirement will be for 240 volts and all you should need is a 240 volt 3-wire receptacle. The installation manual that comes with the charger will provide the power requirements and also tell you what NEMA configuration receptacle that is needed.
By TomB2 on November 4, 20175
Answers
I just did. My electric box had a ground wire which is what is the 4th plug is hooked to . It was a little tight but it worked.
By Chucknite on December 21, 2018Don't do it! This is a violation of the National Electrical Code (also known as the National Fire Protection Association Article #70), as well as most local building codes. Leaving the ground terminal unconnected could present a severe, i.e., fatal shock hazard. In addition, if an electrical fire starts in the house, even if it doesn't start in this circuit, could be grounds for your insurance company to deny your damage claim as a result of unsafe wiring practices by unlicensed personnel. Do yourself a favor and do it right, either by using an approved three-prong outlet for the existing wiring, or by hiring a licensed, professional electrician to re-wire the circuit for a four-wire, grounded outlet as specified in the latest edition of the Code (2017).
By Microbob1984 on March 13, 2018You shouldn't. Someone may damage their equipment by thinking the fourth terminal is connected.
By Verified Pro Russell on May 27, 2016A 3 wire with a ground should be red, black, white and green or copper un shielded. Red and Black are the 2 110 source wires one to each pole on the breaker itself. The white is the common to the grounding bar in the panel and the green or copper is ground . The plug side for white has a common wire location, the ground could be to the plug body or a screw.
By Verified Pro Toolman on April 21, 2015This is a 4-wire range receptacle and must have a ground wire for the installation to be safe. It cannot be used on a 3-wire circuit.
By TomB2 on February 13, 20153
Answers
Best to use a 2 1/8" deep 4" square box (1900) with plaster frame OR with a raised cover if a surface application. Lowes sells both.
By TomB2 on June 20, 2024Yes, however should you prefer to use a double gang box, good luck finding a double gang face plate to fit it. Not many stores carry them.
By Jimbo on May 3, 2020Yes it does. However once you get 10 gauge wire in there with it, it is a tight fit. I’ve done it, and you will need to take your time forming the wires to fit
By Jimbo on May 3, 20203
Answers
That would be a code violation. Change the cord on your dryer to a 4-wire with 4-prong plug.
By TomB2 on May 25, 2023No. The 3-plug receptacles and plugs are outdated and can lead to electrocution. They no longer meet code requirements in some jurisdictions.
By ZJDiy on August 20, 2021The outlet itself cannot be changed to a 3 prong however a cord can.
By CommunityAnswer on December 13, 20183
Answers
Yes, it can be wired as such. Unless you know what you are doing and are certain other people won't use it the way it is normally intented, be wary.
By VoltyMcVoltface on January 8, 2022NO! You need the item #409852 for 30 amp 120 volt RV Plug. Diiferent prong arrangement.
By TomG on March 1, 2020No, a 250V 50A RV receptacle has no neutral.
By TomB2 on September 20, 20183
Answers
As long as you are using the proper 4-wire dryer cord/plug the plug will fit this 4-wire dryer receptacle.
By TomB2 on May 1, 2017i bought the outlet anyways and it definitely fit.
By cdwyer on April 5, 2017No, it will not fit.
By CommunityAnswer on April 5, 20172
Answers
This is a 4-wire grounding dryer receptacle.
By TomB2 on May 26, 2023It's exactly backwards. NEMA 10 devices such as this have a neutral ("groundED conductor") but no ground ("equipment groundING conductor")
By Benjamin on October 8, 20202
Answers
No, this receptacle should be wired with 10-3 NM-B cable which has 4 wires in the 30A 120/240 volt circuit.
By TomB2 on May 26, 2023No, the power outlet is only used for a 125/250 volt line.
By CommunityAnswer on March 17, 2019