| What Size Fan Do You Need? |
- Use a 36" diameter ceiling fan if the largest room dimension is 12' or less.
- Use a 42" diameter ceiling fan if the largest room dimension is 12' to 15'.
- Use a 52" diameter ceiling fan if the largest room dimension is 15' to 18'.
|
 |
| Tools & Materials |
Click a text link below to shop for that item.
Click the information icon for a product buying guide.
- Ceiling fan kit
- Outlet
box (ceiling or "paddle" fan installation approved)
- Wire nuts
- Downrod (optional)
- Expandable cross brace (optional)
- Light
bulbs (if fan has lights)
- Ceiling medallion (optional)
- Electrical Tape
|
|
|
 |
| Before You Begin |
To ensure that your fan is securely mounted to the ceiling and for your safety during installation,
read all of the instructions packed with your fan. Since ceiling fans are usually used to replace existing light fixtures,
the wiring to the fan should already be complete. Installation is not difficult,
and only requires that you pay attention to the instructions included with the fan.
If additional wiring must be done to install your fan and you are not familiar with wiring, consult a professional electrician.
All wiring must conform to local and national codes.
 |
When working with electricity always:
- Turn off the power.
- Test the wires to ensure the power is off.
- Lock the panel box, so no one can accidentally turn the power back on while you are working.
- Check with local authorities to see if a permit is required.
- Have your work checked by an inspector.
- Wear eye goggles and a dust mask.
- To avoid overloading the circuit, consult a licensed electrician.
|
| 
|
Read ALL instructions and safety information completely. To
reduce the risk of fire or electric shock, do not use the fan
with any solid-state speed control device or variable speed switch
unless specifically designed for use with a ceiling fan. Do not
mount the ceiling fan to a plastic electrical box. Use a metal
box securely fastened to the building structure.
|
|
 |
| Mounting Options |
Fan blades must be mounted at least seven feet above the floor. For maximum
efficiency, they should not have any obstruction within 24" of the blade tips.
An appropriate junction or outlet box securely attached to the building
structure is required. Replace the old box with one labeled as approved
for ceiling fans or ceiling suspended "paddle" fan installation.
The box and its support must be able to support the moving weight of the
fan. Use the installation hardware recommended by the junction box manufacturer.
Fans of over 35 pounds, with or without accessories, require additional
support independent of the outlet box.
Secure the new box to a brace between ceiling joists. If there is no 2"
x 4" wood brace between the joists but you have access to the framing
through the attic, add a brace. Otherwise, install an expandable metal
ceiling fan hanger bar. These may be positioned either from the attic
or from below the ceiling, through the rough opening. Secure the box to the bracket with a U-bolt.
|
 |
| Installation of Mounting Bracket |
Remove the fan motor screws. These screws will be used later to secure
the blade arms to the motor.
- Remove the mounting bracket from the fan canopy.
- Secure the mounting bracket to the ceiling electrical box with mounting screws
and lock washers. If the fan comes with a J-hook, install the mounting
bracket with the J-hook towards the floor. The hook will support the
weight of the fan motor housing for a hands-free wiring installation.
- Pull the electrical wires through the center hole of the mounting bracket.
- At this point, if you have a fan with a three position mount, you will need
to decide whether to use a close mount or downrod installation. (Downrod
installations are used for both standard and angled applications.)
|
 |
| Downrod Installation |
- Install the downrod into the mount with the ball end toward the ceiling.
- Thread the lead wires from the motor (black, white and blue) through both the
canopy and downrod. Take extra care not to pull on electrical wires.
- Insert the downrod into the collar yoke and rotate until the holes match. Insert
the connector pin through the holes, and secure with a cotter pin. Be
careful not to damage or cut the fan wires. Bend the two legs of the
cotter pin to ensure that the connector pin does not slip out.
Affix the hanger and downrod to the motor assembly by tightening the
setscrew on the side of the downrod. Some fans have two setscrews and
some have lock nuts for the setscrews.
- Insert the ball into the hanger bracket. The tab opposite the hanger bracket
opening should fit into the slot on the ball. Make the appropriate wire connections.
- After the connections are made and the wires are carefully tucked into the
outlet box, make sure the tab in the bottom of the hanger bracket is
seated in the groove of the hanger ball. Slide the canopy up the hanger
bracket and permanently attach it with the supplied screws.
|
 |
| Close Mount Installation |
Some fans allow mounting without the use of a downrod. This type of mount places the fan closer to the ceiling.
Remove
the larger screws and lock washers from the top of the decorative fan motor housing.
- Secure the canopy to the housing using the same screws.
- Hang the fan on the J-hook (if applicable) by using one of the holes at the top of the canopy.
- Make the appropriate wire connections. After the connections
are made and the wires are carefully tucked into the outlet box, remove
the canopy from the J-hook on the mounting plate.
- Permanently attach the canopy to the mounting plate with the provided screws.
|
 |
| Attaching Fan Blades |
- Mount each blade bracket to a fan blade using the screws and washers supplied.
Start all screws before tightening, then tighten each. Repeat for the remaining blades.
- Follow the same process to mount each blade/bracket assembly to the fan. Make sure all screws are tightened securely.
|
 |
| Installing a Light Kit |
If your fan comes with a light kit, it may already be wired and in place
requiring only that you install the bulbs and globes. In some instances,
however, you may need to wire the light kit yourself. Do this as follows.
- Remove the switch housing cover plate from the fan.
- Remove the plug from the center of the cover plate.
- Feed the light kit wires (black and white) through the holes in the cover plate
and screw the plate tightly to the light kit to prevent it from vibrating loose.
- Locate two wires within the switch housing labeled "for light" (white
and blue). Connect them to the light kit wires with wire nutswhite
to white and blue to black. Secure the connections with electrical tape
to prevent the wire nuts from vibrating loose during operation.
- Carefully push wires back into the switch housing, and attach the light kit to the switch housing with the provided screws.
|
ENERGY STAR labeled ceiling fans move at least 20 percent more air than a
typical ceiling fan per watt of power consumed. ENERGY STAR labeled
ceiling fans use about 60-70 percent less electricity for lighting
than equivalent incandescent models.
|
|
 |
|
|
|
If you are not satisfied with the service we provide, we will make it right. Guaranteed.
|
|
 |
Click the button below to sign up for valuable offers and free, COOL informative newsletters for all do-it-yourselfers.
|
|
|
|
Was this information helpful? Please let us know your do-it-yourself experiences. We'd love to hear from you!
These How-To's are provided as a service from Lowe's, the Original Home Improvement Warehouse of How-To information for the World Wide Web. The information in Lowe's "How-To" clinics is intended to simplify jobs around the house. Tools, products, materials, techniques, building codes and local regulations change; therefore, Lowe's assumes no liability for omissions, errors or the outcome of any project. The reader must always exercise reasonable caution, follow current codes and regulations that may apply, and is urged to consult with a licensed professional if in doubt about any procedures. Please read our terms of use.
|
|